Mediant 2000 SIP User’s Manual

J. SS7 Tunneling

J.3 SS7 Parameters

The parameters in Table J-1below configure all MTP attributes simultaneously. To set each MTP attribute individually, add _xx (xx equals the element number in the range of 0 to 2) to the end of the ini file field name.

Table J-1: SS7 Parameters (continues on pages 233 to 234)

ini File Parameter Name

Description

 

 

 

 

SS7_MTP2_Param_AERM_TIE

Defines the SS7 alignment emergency error rate threshold.

 

 

The valid range is 0 to 10.

 

 

The default value is 1.

 

SS7_MTP2_Param_AERM_TIN

Defines the SS7 alignment normal error rate threshold.

 

 

The valid range is 0 to 20.

 

 

The default value is 4.

 

SS7_MTP2_Param_Error_Correction_

Defines the SLI error correction method.

 

Method

0 = Basic (default)

 

 

B = Basic

 

 

P = PCR (Preventive Cyclic Retransmission)

 

SS7_MTP2_Param_IAC_CP

Defines the number of aborted proving attempts before sending an out-of-

 

 

service to MTP-3.

 

 

The valid range is 0 to 10.

 

 

The default value is 5.

 

SS7_MTP2_Param_Link_Rate

Defines the SS7 SLI Link Rate.

 

 

Choose either:

 

 

0 = 64 kbps (default)

 

 

A = 64 kbps

 

 

D = 56 kbps

 

SS7_MTP2_Param_LSSU_Length

Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes).

 

 

The valid range is 1 to 2.

 

 

The default value is 1.

 

SS7_MTP2_Param_Octet_Counting

Defines the SS7 MTP2 Octet received while the OCTET is in counting mode

 

 

(# of Octets received - N Octets - while in Octet counting mode).

 

 

The valid range is 0 to 256.

 

 

The default value is 16.

 

SS7_MTP2_Param_SUERM_SU_D

Defines the SS7 Signal Unit error rate monitor D threshold.

 

 

The valid range is 0 to 256.

 

 

The default value is 256.

 

SS7_MTP2_Param_SUERM_T

Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold.

 

 

The valid range is 0 to 256.

 

 

The default value is 64.

 

SS7_MTP2_Param_Timer_T1

Defines the SS7 MTP2 T1 alignment ready timer (in msecs).

 

 

The valid range is 0 to 100000.

 

 

The default value is 50000.

 

SS7_MTP2_Param_Timer_T2

Defines the SS7 MTP2 T2 unaligned timer (in msecs).

 

 

The valid range is 0 to 200000.

 

 

The default value is 150000.

 

SS7_MTP2_Param_Timer_T3

Defines the SS7 MTP2 T3 timer aligned.

 

 

The valid range is 0 to 20000.

 

 

The default value is 2000.

 

SS7_MTP2_Param_Timer_T4E

Defines the SS7 MTP2 T4e Emergency proving period timer (msec).

 

 

The valid range is 0 to 5000.

 

 

The default value is 500.

 

SS7_MTP2_Param_Timer_T4N

Defines the SS7 MTP2 T4n Nominal proving period timer.

 

 

The valid range is 0 to 15000.

 

 

The default value is 8200.

 

SS7_MTP2_Param_Timer_T5

Defines the SS7 MTP2 Sending SIB timer.

 

 

The valid range is 0 to 2400.

 

 

The default value is 120.

 

Version 4.4

233

July 2005

Page 233
Image 233
Nortel Networks TP-1610 SIP user manual SS7 Parameters