Nortel Networks TP-1610 SIP user manual Snmp Parameters

Models: TP-1610 SIP

1 280
Download 280 pages 4.94 Kb
Page 98
Image 98

Mediant 2000 SIP

6.7SNMP Parameters

Note: In Table 6-2, parameters in brackets are the format in the Embedded Web Server *.

Table 6-2: SNMP Parameter (continues on pages 98 to 99)

 

ini File Field Name

Valid Range and Description

 

Web Parameter Name*

 

DisableSNMP

0 = SNMP is enabled (default).

 

 

[Enable SNMP]

1 = SNMP is disabled and no traps are sent.

 

 

SNMPPort

The device’s local UDP port used for SNMP Get/Set commands.

 

 

The range is 100 to 3999.

 

 

 

The default port is 161.

 

 

SNMPTrustedMGR_x

Up to five IP addresses of remote trusted SNMP managers from which the

 

 

SNMP agent accepts and processes get and set requests.

 

 

Note 1: If no values are assigned to these parameters any manager can

 

 

access the device.

 

 

 

Note 2: Trusted managers can work with all community strings.

 

SNMP Trap Parameters

 

 

 

SNMPManagerTableIP_x

Up to five IP addresses of remote hosts that are used as SNMP Managers. The

 

[SNMP Managers Table]

device sends SNMP traps to these IP addresses.

 

 

 

Enter the IP address in dotted format notation, for example 108.10.1.255.

 

 

Note: The first entry (out of the five) replaces the obsolete parameter

 

 

SNMPManagerIP.

 

 

SNMPManagerTrapPort_x

Up to five parameters used to define the Port numbers of the remote SNMP

 

[SNMP Managers Table]

Managers. The device sends SNMP traps to these ports.

 

 

Note: The first entry (out of the five) replaces the obsolete parameter

 

 

SNMPTrapPort.

 

 

 

The default SNMP trap port is 162

 

 

 

The SNMP trap port must be between 100 to 4000.

 

SNMPManagerIsUsed_x

Up to five parameters, each determines the validity of the parameters (IP

 

[SNMP Managers Table]

address and port number) of the corresponding SNMP Manager used to

 

 

receive SNMP traps.

 

 

 

0 = Disabled (default)

 

 

 

1 = Enabled

 

 

SNMPManagerTrapSendingEnable_x

Up to five parameters, each determines the activation/deactivation of sending

 

[SNMP Managers Table]

traps to the corresponding SNMP Manager.

 

 

 

0 = Sending is disabled

 

 

 

1 = Sending is enabled (default)

 

 

SNMPManagerIP

IP address (in dotted format notation) for the computer that is used as the first

 

Note: Obsolete parameter, use

SNMP Manager. The SNMP Manager is a device that is used for receiving

 

SNMP Traps.

 

 

SNMPManagerTableIP_x instead.

Note 1: To enable the device to send SNMP Traps, set the ini file parameter

 

 

 

 

SNMPManagerIsUsed to 1.

 

 

 

Note 2: If you want to use more than one SNMP manger, ignore this parameter

 

 

and use the parameters ‘SNMPManagerTableIP_x’ instead.

 

SNMP Community String Parameters

 

 

 

SNMPReadOnlyCommunityString_x

Read-only community string (up to 19 chars).

 

 

 

The default string is “public”.

 

 

SNMPReadWriteCommunityString_x

Read-write community string (up to 19 chars).

 

 

 

The default string is “private”.

 

 

SNMPTrapCommunityString_x

Community string used in traps (up to 19 chars).

 

 

 

The default string is “trapuser”.

 

 

 

 

 

 

Mediant 2000 SIP User’s Manual

98

Document #: LTRT-72504

Page 98