ini File Parameter Name

Description

 

 

 

 

SS7_LOCAL_SCTP_PORT

Determines the SIGTRAN group SCTP port.

 

 

The valid range is 0 to 0xFFFE.

 

 

The default value is 0Xfffe.

 

SS7_SIG_NETWORK

Determines the SIGTRAN group Network (ITU, ANSI, CHINA).

 

 

The valid range is 1 to 3.

 

 

The default value is 1.

 

SS7_DEST_SCTP_PORT

Determines the SIGTRAN group destination SCTP port.

 

 

The valid range is 0 to 0xFFFE.

 

 

The default value is 0xFFFE.

 

SS7_DEST_IP

Determines the SIGTRAN group destination IP Address

 

 

The valid range is 0 to 0xFFFFFFFE.

 

 

The default value is 0.

 

SS7_MGC_MX_IN_STREAM

Determines the SIGTRAN group maximum inbound stream.

 

 

The valid range is 2 to 0xFFFE.

 

 

The default value is 2.

 

SS7_MGC_NUM_OUT_STREAM

Determines the SIGTRAN group's number of outbound streams.

 

 

The valid range is 2 to 0xFFFE.

 

 

The default value is 2.

 

J.4.2 SIGTRAN Interface IDs

 

Table J-3: SIGTRAN Interface IDs

 

 

 

 

ini File Parameter Name

 

 

Description

 

 

 

 

SS7_SIG_IF_ID_INDEX

 

Determines the SS7 interface ID index, for a line.

 

 

The valid range is 0 to 15.

 

 

The default value is 1.

SS7_SIG_IF_ID_VALUE

 

Determines the SIGTRAN interface ID value.

 

 

The valid range is 0 to 0xFFFFFFFE.

 

 

The default value is 0.

SS7_SIG_IF_ID_NAME

 

Determines the SIGTRAN interface ID (text string).

 

 

The default string is ‘INT_ID’.

SS7_SIG_IF_ID_OWNER_GROUP

 

Determines the SIGTRAN interface ID owner group.

 

 

The valid range 0 to 0xFFFE.

 

 

The default value is 0.

SS7_SIG_IF_ID_LAYER

 

Determines the SIGTRAN group layer (IUA/M2UA/M3UA).

 

 

0

= no_layer (default)

 

 

1

= iua

 

 

2

= m2ua

 

 

3

= m3ua

 

 

4

= m2tunnel

 

 

5

= V5ua

SS7_SIG_IF_ID_NAI

 

Determines the SIGTRAN interface ID NAI.

 

 

The valid range 0 to 0xFFFE.

 

 

The default value is 0xFFFE.

SS7_SIG_M3UA_SPC

 

Determines the SIGTRAN M3UA SPC.

 

 

The valid range 0 to 0xFFFFFFFE.

 

 

The default value is 0.