Mediant 2000 SIP User’s Manual

5. Web Management

 

Table 5-6: Channel Select Modes

 

 

Mode

Description

 

 

By phone number

Select the gateway port according to the called number (refer to the note

 

below).

Cyclic Ascending

Select the next available channel in an ascending cycle order. Always select

 

the next higher channel number in the Trunk Group. When the gateway

 

reaches the highest channel number in the Trunk Group, it selects the lowest

 

channel number in the Trunk Group and then starts ascending again (default).

Ascending

Select the lowest available channel. Always start at the lowest channel

 

number in the Trunk Group and if that channel is not available, select the next

 

higher channel.

Cyclic Descending

Select the next available channel in descending cycle order. Always select the

 

next lower channel number in the Trunk Group. When the gateway reaches

 

the lowest channel number in the Trunk Group, it selects the highest channel

 

number in the Trunk Group and then start descending again.

Descending

Select the highest available channel. Always start at the highest channel

 

number in the Trunk Group and if that channel is not available, select the next

 

lower channel.

Number + Cyclic Ascending

First select the gateway port according to the called number (refer to the note

 

below). If the called number isn’t found, then select the next available channel

 

in ascending cyclic order. Note that if the called number is found, but the port

 

associated with this number is busy, the call is released.

Note: The internal numbers of the gateway’s B-channels are defined in the ‘Trunk Group Table’ under the ‘Phone Number’ column. For detailed information on the ‘Trunk Group Table’, refer to Section 5.8.6 on page 58).

Version 4.4

61

July 2005

Page 61
Image 61
Nortel Networks TP-1610 SIP user manual Channel Select Modes, Mode Description