Nortel Networks TP-1610 SIP Configuring the TDM Bus Settings, 18TDM Bus Settings Screen

Models: TP-1610 SIP

1 280
Download 280 pages 4.94 Kb
Page 68
Image 68

Mediant 2000 SIP

Click the Close Window button.

7.After modifying the parameters:

To apply the changes to the selected trunk only, click the Apply Trunk Settings button. To apply the changes to all the trunks, click the Apply to all Trunks button.

The screen is refreshed, parameters become read-only (indicated by being grayed). The Stop Trunk button appears at the bottom of the screen.

8.To save the changes so they are available after a power fail, refer to Section 5.12 on page 84.

Note: Some parameter configuration options require a device reset; when this is the case, the Web Interface prompts the user.

9. To reset the Mediant 2000, refer to Section 5.12 on page 84.

5.9.4Configuring the TDM Bus Settings

To configure the TDM Bus Settings parameters, take these 5 steps:

1.Open the ‘TDM Bus Settings’ screen (Advanced Configuration menu > TDM Bus Settings); the ‘TDM Bus Settings’ screen is displayed.

2.Configure the TDM Bus Settings parameters.

3.Click the Submit button to save your changes.

4.To save the changes so they are available after a power fail, refer to Section 5.12 on page 84.

5.A device reset is required to activate the TDM Bus Settings parameters. To reset the Mediant 2000, refer to Section 5.12 on page 84.

Figure 5-18:TDM Bus Settings Screen

Note: Usually the ‘PCM Law Select’ parameter is set to A-law for E1 trunks and to -law for T1 trunks.

Refer to Appendix E on page 205 for information on configuring the ‘TDM Bus Clock Source’, ‘TDM Bus Enable Fallback’ and ‘TDM Bus PSTN Auto Clock’ parameters.

Mediant 2000 SIP User’s Manual

68

Document #: LTRT-72504

Page 68
Image 68
Nortel Networks TP-1610 SIP user manual Configuring the TDM Bus Settings, 18TDM Bus Settings Screen