Mediant 2000 SIP User’s Manual

L. SNMP Traps

Appendix L SNMP Traps

This section provides information on proprietary SNMP traps currently supported by the gateway. There is a separation between traps that are alarms and traps that are not (logs). Currently all have the same structure made up of the same 10 varbinds (Variable Binding) (1.3.6.1.4.1.5003.9.10.1.21.1).

L.1 Alarm Traps

The following tables provide information on alarms that are raised as a result of a generated SNMP trap. The component name (described in each of the following headings) refers to the string that is provided in the ‘acBoardTrapGlobalsSource’ trap varbind. To clear a generated alarm the same notification type is sent but with the severity set to ‘cleared’.

L.1.1 Component: System#0

 

Table L-1: acBoardFatalError Alarm Trap

 

 

Alarm:

acBoardFatalError

OID:

1.3.6.1.4.1.5003.9.10.1.21.2.0.1

Default Severity

Critical

Event Type:

equipmentAlarm

Probable Cause:

underlyingResourceUnavailable (56)

Alarm Text:

Board Fatal Error: <text>

Status Changes:

 

Condition:

Any fatal error

Alarm status:

Critical

<text> value:

A run-time specific string describing the fatal error

 

 

Condition:

After fatal error

Alarm status:

Status stays critical until reboot. A clear trap is not sent.

Corrective Action:

Capture the alarm information and the Syslog clause, if active. Contact your first-level

 

support group. The support group will likely want to collect additional data from the

 

device and perform a reset.

 

Table L-2: acBoardConfigurationError Alarm Trap

 

 

 

Alarm:

 

acBoardConfigurationError

OID:

 

1.3.6.1.4.1.5003.9.10.1.21.2.0.2

Default Severity

 

Critical

Event Type:

 

equipmentAlarm

Probable Cause:

 

underlyingResourceUnavailable (56)

Alarm Text:

 

Board Config Error: <text>

Status Changes:

 

 

Condition:

 

A configuration error was detected

Alarm status:

 

critical

<text> value:

 

A run-time specific string describing the configuration error.

 

 

 

Condition:

 

After configuration error

Alarm status:

 

Status stays critical until reboot. A clear trap is not sent.