Nortel Networks TP-1610 SIP user manual Configuring the Mediant 2000 Basic Parameters

Models: TP-1610 SIP

1 280
Download 280 pages 4.94 Kb
Page 37
Image 37

Mediant 2000 SIP User’s Manual

4. Getting Started

This option is currently supported on one media gateway module (trunks 1-8) only.

To restore networking parameters to their initial state, take these 6 steps:

1.Disconnect the Mediant 2000 from the power and network cables.

2.Reconnect the power cable; the gateway is powered up. After approximately 45 seconds the ACT LED blinks for about 4 seconds.

3.While the ACT LED is blinking, press shortly on the reset button (located on the front panel); the gateway resets a second time and is restored with factory default parameters (username: “Admin”, password: “Admin”).

4.Reconnect the network cable.

5.Assign the Mediant 2000 IP address (refer to Section 4.1 on page 35).

6.Load your previously backed-up ini file, or the default ini file (received with the software kit). To load the ini file via the Embedded Web Server, refer to Section 5.9.5 on page 69.

4.3Configuring the Mediant 2000 Basic Parameters

To configure the Mediant 2000 basic parameters use the Embedded Web Server’s ‘Quick Setup’

screen (shown in Figure 4-1below). Refer to Section 5.6 on page 41 for information on accessing the ‘Quick Setup’ screen.

Figure 4-1: Mediant 2000 Quick Setup Screen

To configure basic SIP parameters, take these 10 steps:

1.If the Mediant 2000 is connected to a router with NAT (Network Address Translation) enabled, perform the following procedure. If it isn’t, leave the ‘NAT IP Address’ field undefined.

Determine the “public” IP address assigned to the router (by using, for instance, router Web management). Enter this public IP address in the ‘NAT IP Address’ field.

Version 4.4

37

July 2005

Page 37