Mediant 2000 SIP User’s Manual

2. Mediant 2000 Physical Description

2.3.2TP-1610 Front Panel LED Indicators

The functionality of the front panel LEDs for the TP-1610 is described in the following four tables and illustrated in Figure 2-2on page 21. Note that there is a choice of front panels according to the number of channels.

Table 2-4: Status LED Indicators

 

Label

LED Color

 

 

LED Function

 

 

FAIL

Red

Normally OFF; Red indicates gateway failure (fatal error)

 

 

ACT

Green

Gateway initialization sequence terminated OK

Bi-color

 

Yellow

N/A

 

LED

 

 

 

 

 

 

 

 

Table 2-5: E1/T1 Trunk Status LED Indicators

 

 

 

 

 

 

 

 

 

 

 

Label

LED Color

 

 

Signal Description

 

 

 

 

Green

Trunk is synchronized (normal operation)

Bi-color

 

T1/E1 Status 1 to 8

Red

Loss due to any of the following 4 signals:

LED

 

 

 

 

 

LOS

 

Loss of Signal

 

 

and

 

 

 

 

 

T1/E1 Status 9 to 16

 

 

LFA

 

Loss of Frame Alignment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIS

 

Alarm Indication Signal (the Blue Alarm)

 

 

 

 

 

 

RAI

 

Remote Alarm Indication (the Yellow Alarm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

On the front panel 16 LEDs are provided for 16-span units and 8 LEDs are

 

 

 

 

provided for 1-span, 2-span, 4-span, and 8-span units. In the case of 1-span,

 

 

 

 

2-span and 4-span units, the extra LEDs are unused.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2-6: Ethernet LED Indicators

 

 

 

 

 

 

 

 

 

Label

LED Color

 

 

LED Function

 

 

LINK

Green

Link all OK

 

 

 

ACT

Yellow

Transmit / receive activity

 

 

 

 

 

 

Table 2-7: cPCI LED Indicators

 

 

 

 

 

 

 

 

 

Label

LED Color

 

 

LED Function

 

 

PWR

Green

Power is supplied to the board

 

 

 

 

 

 

The cPCI board can now be removed.

 

 

SWAP READY

Blue

The cPCI board was inserted successfully.

 

 

For detailed information on the Swap-Ready LED, refer to Section

 

 

 

 

 

 

 

 

 

 

2.3.1 on page 21.

 

During correct Mediant 2000 operation, the ACT LED is lit green, the FAIL LED is off. Changing of the FAIL LED to red indicates a failure.

Version 4.4

23

July 2005

Page 23