Dell HR675 PCIe Fatal Error, Caused a system, Reset Slot n, Embedded, Bus#nn/Dev#nn/Func, Remote

Models: HR675

1 194
Download 194 pages 21.08 Kb
Page 35
Image 35

Table 1-6. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

PCIe Fatal Error

Faulty or improperly

Reseat the PCIe card in the

caused a system

installed PCIe card in the

specified slot number (see

reset: Slot n

specified slot.

"Installing an Expansion

Embedded

 

Card" on page 95). If the

 

problem persists, see

Bus#nn/Dev#nn/Func

 

 

"Getting Help" on page 175.

n

 

 

 

Please check the

 

 

system event log

 

 

for details

 

 

 

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration Error initializing PCIe device;

jumper and reboot the

 

faulty system board.

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

"Troubleshooting Expansion Cards" on page 159.

Read fault

Requested sector not found

The operating system cannot read from the hard drive or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

Replace the USB medium or device. Ensure that the USB or hard drive cables are properly connected. See "Troubleshooting a USB Device" on page 138, or "Troubleshooting a Hard Drive" on page 153 for the appropriate drive(s) installed in your system.

Remote

System unable to process

Retry Remote Configuration.

configuration

Remote Configuration

 

update attempt

request.

 

failed

 

 

 

 

 

ROM bad checksum =

Expansion card

Reseat the expansion card(s)

address

improperly installed or

and expansion card cables. If

 

faulty.

the problem persists, see

 

 

"Troubleshooting Expansion

 

 

Cards" on page 159.