Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E201C

SMI Init

System management

See "Getting Help" on

 

 

interrupt (SMI)

page 175.

 

 

initialization failure.

 

 

 

 

E201D

Shutdown Test BIOS shutdown test failure.

See "Getting Help" on

 

 

 

page 175.

E201E POST Mem Test BIOS POST memory test failure.

See "Troubleshooting System Memory" on page 146. If the problem persists, see "Getting Help" on page 175.

E201F

DRAC Config

Remote Access Controller

Check screen for specific

 

 

(RAC) configuration failure. error messages. Ensure

 

 

 

that RAC cables and

 

 

 

connectors are properly

 

 

 

seated. If problem

 

 

 

persists, see your RAC

 

 

 

documentation.

 

 

 

 

E2020

CPU Config

CPU configuration failure.

Check screen for specific

 

 

 

error messages.

 

 

 

 

E2021

Memory

Incorrect memory

Check screen for specific

 

Population

configuration. Memory

error messages (see

 

 

population order incorrect.

"Troubleshooting System

 

 

 

Memory" on page 146).

 

 

 

 

E2022

POST Fail

General failure after video.

Check screen for specific

 

 

 

error messages.

 

 

 

 

E2110

MBE DIMM # &

One of the DIMMs in the

See "Troubleshooting

 

#

set implicated by "# & #"

System Memory" on

 

 

has had a memory multi-bit

page 146.

 

 

error (MBE).

 