E1227 | Linear PwrGd | Linear voltage regulator(s) has failed. Represents | See Getting Help. |
|
| status of multiple voltage regulators used in the |
|
|
| video and LOM circuitry. |
|
|
|
|
|
E1229 | CPU # VCORE | Processor # VCORE voltage regulator has failed. | See Getting Help. |
|
|
|
|
E122A | CPU VTT PwrGd | Processor # VTT voltage has exceeded the | See Getting Help. |
|
| allowable voltage range |
|
E122D | CPU # VDDIO | Processor # VDDIO voltage has exceeded the | See Getting Help. |
|
| allowable voltage range |
|
| 1.0V PwrGd |
|
|
|
|
|
|
E122E | CPU # VDDA | Processor # VDDA voltage has exceeded the | See Getting Help. |
|
| allowable voltage range |
|
E122F | 2.5V PwrGd | 2.5V voltage regulator has failed. | See Getting Help. |
E1231 | 1.2V HTCORE PwrGd | 1.2V HTCORE voltage regulator has failed. | See Getting Help. |
|
|
|
|
E1232 | VDD 12V PS# PwrGd | The specified power supply has failed or has been | If removed, reinsert the power supply into the bay and reconnect to power. |
|
| removed from the bay while the system was on. | For component failures, see Getting Help. |
|
|
|
|
E123B | LOM Mezz PwrGd | Voltage regulator for the LOM daughter card has | Recycle power to the system or clear the SEL. If the problem persists, see |
|
| failed. | Getting Help. |
|
|
|
|
E123C | Planar LOM PwrGd | Voltage regulator for the integrated LOM has | Recycle power to the system or clear the SEL. If the problem persists, see |
|
| failed. | Getting Help. |
E1310 | RPM Fan ## | RPM of specified cooling fan is out of acceptable | See Troubleshooting System Cooling Problems. |
|
| operating range. |
|
E1313 | Fan Redundancy | The system is no longer | Check control panel LCD for additional scrolling messages. See |
|
| fan failure will put the system at risk of over- | Troubleshooting System Cooling Problems. |
|
| heating. |
|
|
|
|
|
E1414 | CPU # Thermtrip | Specified microprocessor is out of acceptable | See Troubleshooting System Cooling Problems. If the problem persists, |
|
| temperature range and has halted operation. | ensure that the microprocessor heat sinks are properly installed. See |
|
|
| Troubleshooting the Microprocessors. |
|
|
| NOTE: The LCD continues to display this message until the system's power |
|
|
| cord is disconnected and reconnected to the AC power source, or the SEL is |
|
|
| cleared using either Server Assistant or the BMC Management Utility. See |
|
|
| the Dell OpenManage™ Baseboard Management Controller User's Guide for |
|
|
| information about these utilities. |
|
|
|
|
E1418 | CPU # Presence | Specified processor is missing or bad, and the | See Troubleshooting the Microprocessors. |
|
| system is in an unsupported configuration. |
|
E141C | CPU Mismatch | Processors are in a configuration unsupported by | Ensure that your processors match and conform to the type described in |
|
| Dell. | the Microprocessor Technical Specifications outlined in your system's Getting |
|
|
| Started Guide. |
|
|
|
|
E141F | CPU Protocol | The system BIOS has reported a processor | See Getting Help. |
|
| protocol error. |
|
|
|
|
|
E1421 | CPU Init | The system BIOS has reported a processor | See Getting Help. |
|
| initialization error. |
|
E1422 | CPU Machine Chk | The system BIOS has reported a machine check | See Getting Help. |
|
| error. |
|
E1610 | PS # Missing | No power is available from the specified power | See Troubleshooting Power Supplies. |
|
| supply; specified power supply is improperly |
|
|
| installed or faulty. |
|
|
|
|
|
E1614 | PS # Status | No power is available from the specified power | See Troubleshooting Power Supplies. |
|
| supply; specified power supply is improperly |
|
|
| installed or faulty. |
|
|
|
|
|
E1618 | PS # Predictive | Power supply voltage is out of acceptable range; | See Troubleshooting Power Supplies. |
|
| specified power supply is improperly installed or |
|
|
| faulty. |
|
|
|
|
|
E161C | PS # Input Lost | Power source for specified power supply is | Check the AC power source for the specified power supply. If the problem |
|
| unavailable, or out of acceptable range. | persists, see Troubleshooting Power Supplies. |
E1620 | PS # Input Range | Power source for specified power supply is | Check the AC power source for the specified power supply. If the problem |
|
| unavailable, or out of acceptable range. | persists, see Troubleshooting Power Supplies. |
|
|
|
|
E1624 | PS Redundancy | The power supply subsystem is no longer | See Troubleshooting Power Supplies. |
|
| redundant. If the last supply fails, the system will |
|
|
| go down. |
|
|
|
|
|
E1625 | PS AC Current | Power source is out of acceptable range. | Check the AC power source. |
E1710 | I/O Channel Chk | The system BIOS has reported an I/O channel | See Getting Help. |
|
| check. |
|
|
|
|
|
E1711 | PCI PERR B## D## | The system BIOS has reported a PCI parity error | Remove and reseat the PCIe expansion cards. If the problem persists, see |
| F## | on a component that resides in PCI configuration | Troubleshooting Expansion Cards. |
|
| space at bus ##, device ##, function ##. |
|
| PCI PERR Slot # | The system BIOS has reported a PCI parity error | Reinstall the |
|
| on a component that resides in the specified PCIe |
|
|
| slot. | If the problem persists, the riser card or system board is faulty. See Getting |
|
|
| |
|
|
| Help. |
|
|
|
|
E1712 | PCI SERR B## D## | The system BIOS has reported a PCI system error | Remove and reseat the PCIe expansion cards. If the problem persists, see |
| F## | on a component that resides in PCI configuration | Troubleshooting Expansion Cards. |
|
| space at bus ##, device ##, function ##. |
|
| PCI SERR Slot # | The system BIOS has reported a PCI system error | Reinstall the |