on a component that resides in the specified slot.

 

 

 

 

If the problem persists, the riser card or system board is faulty. See Getting

 

 

 

Help.

 

 

 

 

E1714

Unknown Err

The system BIOS has determined that there has

See Getting Help.

 

 

been an error in the system, but is unable to

 

 

 

determine its origin.

 

E171F

PCIE Fatal Err

The system BIOS has reported a PCIe fatal error

Remove and reseat the PCIe expansion cards. If the problem persists, see

 

B## D## F##

on a component that resides in PCIe configuration

Troubleshooting Expansion Cards.

 

 

space at bus ##, device ##, function ##.

 

 

PCIE Fatal Err

The system BIOS has reported a PCIe fatal error

Reinstall the expansion-card riser. See Expansion-Card Risers.

 

Slot #

on a component that resides in the specified slot.

 

 

 

 

If the problem persists, the riser card or system board is faulty. See Getting

 

 

 

Help.

E1810

HDD ## Fault

The SAS subsystem has determined that hard

See Troubleshooting a Hard Drive.

 

 

drive ## has experienced a fault.

 

 

 

 

 

E1811

HDD ## Rbld Abrt

The specified hard drive has experienced a rebuild

See Troubleshooting a Hard Drive. If the problem persists, see your RAID

 

 

abort.

documentation.

 

 

 

 

E1812

HDD ## Removed

The specified hard drive has been removed from

Information only.

 

 

the system.

 

 

 

 

 

E1914

DRAC5 Conn2 Cbl

DRAC 5 cable is missing or disconnected.

Reconnect the cable. See Installing a RAC Card.

 

 

 

 

E1915

IO55 HTSink

Heatsink sensor reports that the chipset IO55

See Getting Help.

 

Missing

heatsink is missing.

 

 

MCP55 Htsink

Heatsink sensor reports that the chipset MCP

 

 

Missing

heatsink heatsink is missing.

 

 

 

 

E1A12

PCI Rsr Missing

One or all of the PCIe risers is missing, preventing

Reinstall the missing riser card(s).

 

 

the system from powering on.

 

 

 

 

 

E1A14

SAS Cable A

SAS cable A is missing or bad.

Reseat the cable. If the problem persists, replace cable. See SAS Controller

 

 

 

Daughter Card.

 

 

 

 

E1A15

SAS Cable B

SAS cable B is missing or bad.

Reseat the cable. If the problem persists, replace cable. See SAS Controller

 

 

 

Daughter Card.

 

 

 

 

E1A1C

LOM Mezz Missing

LOM daughter card is missing.

Install or reseat the LOM daughter card. If the problem persists, replace the

 

 

 

card. See Getting Help.

E1B01

USB# Overcurrent

Device plugged in the specified USB port caused

Reseat the device cable. If the problem persists, replace or remove the

 

 

an overcurrent condition.

device.

E2010

No Memory

No memory is installed in the system.

Install memory. See Installing Memory Modules.

E2011

Mem Config Err

Memory detected, but is not configurable. Error

See Troubleshooting System Memory.

 

 

detected during memory configuration.

 

 

 

 

 

E2012

Unusable Memory

Memory is configured, but not usable. Memory

See Troubleshooting System Memory.

 

 

subsystem failure.

 

 

 

 

 

E2013

Shadow BIOS Fail

The system BIOS failed to copy its flash image into

See Troubleshooting System Memory.

 

 

memory.

 

 

 

 

 

E2014

CMOS Fail

CMOS failure. CMOS RAM not functioning properly.

See Getting Help.

 

 

 

 

E2015

DMA Controller

DMA controller failure.

See Getting Help.

 

 

 

 

E2016

Int Controller

Interrupt controller failure.

See Getting Help.

 

 

 

 

E2017

Timer Fail

Timer refresh failure.

See Getting Help.

 

 

 

 

E2018

Prog Timer

Programmable interval timer error.

See Getting Help.

 

 

 

 

E2019

Parity Error

Parity error.

See Getting Help.

 

 

 

 

E201A

SIO Err

SIO failure.

See Getting Help.

E201B

Kybd Controller

Keyboard controller failure.

See Getting Help.

 

 

 

 

E201C

SMI Init

System management interrupt (SMI) initialization

See Getting Help.

 

 

failure.

 

 

 

 

 

E201D

Shutdown Test

BIOS shutdown test failure.

See Getting Help.

 

 

 

 

E201E

POST Mem Test

BIOS POST memory test failure.

See Troubleshooting System Memory. If problem persists, see Getting Help.

E201F

DRAC Config

Dell remote access controller (DRAC) configuration

Check screen for specific error messages.

 

 

failure.

 

 

 

 

Ensure that DRAC cables and connectors are properly seated. If problem

 

 

 

persists, see your DRAC documentation.

 

 

 

 

E2020

CPU Config

CPU configuration failure.

Check screen for specific error messages.

 

 

 

 

E2021

Memory Population

Incorrect memory configuration. Memory

Check screen for specific error messages. See Troubleshooting System

 

 

population order incorrect.

Memory.

E2022

POST Fail

General failure after video.

Check screen for specific error messages.

 

 

 

 

E2110

MBE DIMM # & #

One of the DIMMs in the set implicated by "# & #"

See Troubleshooting System Memory.

 

 

has had a memory multi-bit error (MBE).

 

E2111

SBE Log Disable

The system BIOS has disabled memory single-bit

See Troubleshooting System Memory.

 

DIMM #

error (SBE) logging, and will not resume logging

 

 

 

further SBEs until the system is rebooted. "#"

 

 

 

represents the DIMM implicated by the BIOS.

 

 

 

 

 

E2112

Mem Spare DIMM #

The system BIOS has spared the memory because

See Troubleshooting System Memory.

 

 

it has determined that the memory had too many

 

 

 

errors. "# & #" represents the DIMM pair

 

 

 

implicated by the BIOS.

 

 

 

 

 

 

 

 

 

Page 8
Image 8
Dell R805 manual See Troubleshooting a Hard Drive, Daughter Card, Card. See Getting Help, See Troubleshooting System Memory