Epsilon Ei DeviceNet Drive Reference Manual

Master Configuration

RS Networx™ will be used to install the Ei-DN onto the DeviceNet network as a slave. In order to have RS Networx recognize the Ei-DN as a node on the network, an .eds file must be installed using the .eds wizard found under the Tools menu. The .eds file is located in the Emerson directory under Emerson\PtoolsFM\Ei.eds. An icon file can also be found in this directory under Emerson\PtoolsFM\Ei.ico. This icon file will display the Ei-DN graphically in RSnetworx.

Once the .eds file is installed, add a 1747.SDN DeviceNet master to the network set for MacID 0 and an Ei-DN set for MacID 1.

Figure 16: RS Networx Configuration

Double-click the 1747.SDN to bring up the Master Configuration.

48

Page 60
Image 60
Emerson 400501-08 manual Master Configuration, RS Networx Configuration