Network Configuration Quick Start

Figure 14: DN Setup / Index Type

3.Click the Inputs tab to configure the DN bits that will be written from the PLC (Master Send). The following assignments will be used for this application example:

DN Bit00 (MS) = Reset

DN Bit01 (MS) = Home Initiate

DN Bit02 (MS) = Jog +

Note

Index type allows 8 DN bits to be configured. Although these bits are optional to assign, bandwidth used on the DeviceNet network remains the same.

4.Click the Outputs tab to configure the DN bits that will be written from the PLC (Master Receive).

DN Bit00 (MR) = End of Index

DN Bit01 (MR) = End of Home

DN Bit02 (MR) = In + Motion

DN Bit03 (MR) = In - Motion

DN Bit04 (MR) = Fault

DN Bit05 (MR) = Drive OK

43

Page 55
Image 55
Emerson 400501-08 manual DN Setup / Index Type