Troubleshooting

Figure 91 Warning history

01 03/10/05 11:43 W

AUX POWER LOW

02 03/10/05 10:37 W

VIB INOPERATIVE

03 02/24/05 04:03 W

OVERSPEED

04 01/30/05 23:22 W

STATOR HOT

05 12/20/04 13:45 W

ROTOR HOT

06 11/13/04 07:28 W

RUNOUT

07 09/30/04 16:23 W

VACUUM

 

NEXT DONE

Figure 92 Fault history

01

03/10/05 11:43 F CURRENT OFFSET

02

03/10/05 10:37 F CHECKSUM

 

03

02/24/05 04:03 F SOFTWARE OV

 

04

01/30/05 23:22 F DC BUS OV

 

05

12/20/04 13:45 F SPARE OPEN

 

06

11/13/04 07:28 F INTER PROCR COMM

07

09/30/04 16:23 F MISER

 

RESET

NEXT DONE

The warnings, fault meanings and possible causes in the following text and in Table 15 may be used in troubleshooting the messages and may also aid in identifying conditions outside the flywheel sys- tem that may adversely affect it.

8.2Warnings

A Warning is an indication of an abnormal system condition significant enough to warrant being annunciated and logged. Warning conditions may indicate that a system parameter is out of its nor- mal operating range, or may signal an external problem. A Warning indication is for information only and does not require any operator intervention for continued operation of the unit. While in Warning condition, normal operation of the unit will continue unimpeded. A warning can indicate an operating condition that warrants observation and may require preventative maintenance.

Figure 93 Warning screen

Liebert FS

D V U C

 

CHARGE

 

RPM:

39562

MODE:

 

SOC:

45.4%

 

 

 

SOC:

STATUS:

2 WARNINGS

 

BUS:

538V

 

PWR:

32.3kW

 

 

 

 

SHUTDN

LOCK

MORE

MENU

 

Warning Status Message

 

More information

 

 

 

Button (F5)

The Warning condition is indicated by the System Status field displaying “WARNING” in the Control Panel window (see Figure 93). If one Warning is present, the Warning Label (see Table 15.) will be displayed.

While the Warning condition exists, and if more than one Warning is present, F5 the “More Info” key will be enabled in the Control Panel window. If pressed, the separate Warning Labels will be dis- played in the Control Panel window.

Any of eight warnings could occur while the Liebert FS is operating. Warnings give advance alert of potential problems and schedule service and preventive maintenance. These can be monitored and investigated through the use of data from the Control Panel and system tests.