2.1.4Visibility of tags

Getting Started continued

2.1.4Visibility of tags

For personal and system safety, all tags attached to the transmitter housing must remain visible. Clean or replace them as necessary.

2.2Transmitters approved for ATEX Zone 1

WARNING

Explosion hazard

The circuit board compartment is rated EEx d (flameproof), and should remain closed at all times after the flowmeter has been installed.

To avoid risk of explosion in an explosive atmosphere:

Read label that points to compartment cover before accessing circuit board compartment. Figure 2-2 shows the location of the labels on the transmitter housing.

Shut off power, and wait at least 2 minutes before removing EEx d (circuit board) compartment cover. Figure 2-2 also identifies the EEx e (field wiring), EEx i (sensor wiring), and EEx d (circuit board) compartments.

If the transmitter carries an ATEX Zone 1 approval, wiring compartments are labeled as shown in Figure 2-2.

The sensor wiring compartment is rated EEx i (intrinsically safe), and may be opened at any time. See Label 1 in Figure 2-2.

The field wiring compartment is rated EEx e (increased safety), and should remain closed when power is on. See Label 2 in Figure 2-2.

The circuit board compartment is rated EEx d (flameproof), and should remain closed at all times after the transmitter has been installed. If the transmitter is approved by ATEX as flameproof, the compartment has a lockout device, shown in Figure 2-2. The lockout device must be loosened and rotated before the compartment cover can be unscrewed.