Power Supply and Output Wiring continued

Figure 4-6 Wiring to pulse counter with internal pull-up resistor

Pulse counter with pull-up to internal power

Input

Ground (–)

Frequency in (+)

IFT9701 pulse

output terminals

Figure 4-7 Wiring to pulse counter without internal pull-up resistor

Pulse counter with no pull-up

Input

Ground (–)

Frequency in (+)

External 5–30 VDC

power supply

Pull-up resistor

To determine the value of the pull-up resistor, see the graph earlier in this section.

IFT9701 pulse

output terminals

26

Model IFT9701 Transmitter Instruction Manual

Page 34
Image 34
Emerson IFT9701 instruction manual Wiring to pulse counter with internal pull-up resistor