Chapter 4

Power Supply and Output Wiring

4.1Overview

To wire the transmitter power supply and outputs:

Review the wiring guidelines (see Section 4.2)

Connect the power supply wiring (see Section 4.3)

Connect the output wiring (see Section 4.4)

4.2Wiring guidelines

Install cable and wiring so they meet local code requirements.

The transmitter has two separate ¾-inch NPT or M20 female conduit openings, which must remain sealed to keep the transmitter watertight. See Figure 4-1 and Figure 4-2.

The transmitter has a sensor wiring compartment for intrinsically safe sensor wiring, and a field wiring compartment for non-intrinsically safe power supply and output wiring. See Figure 4-1 and Figure 4-2.

-For power supply and output wiring, loosen the four captive screws that secure the cover of the field wiring compartment.

-Access to the sensor wiring and circuit board compartments is not required for power supply and output wiring.

Before You Begin

Getting Started

Mounting the Remote Transmitter

Power Supply and Output Wiring

Model IFT9701 Transmitter Instruction Manual

19

Page 27
Image 27
Emerson IFT9701 instruction manual Power Supply and Output Wiring, Wiring guidelines