Power Supply Requirements, Specifications, and Twist Lock Options
Table A-3 Module Power Specifications
| @ 110 Vac / 220 Vac | |
|
|
|
Module | Power (Watts) | Thermal Output (BTU/HR) |
|
|
|
CM | 97 Watts | 331.1 BTU/HR |
|
|
|
Fan tray | 85 Watts | 290.1 BTU/HR |
|
|
|
30 Watts | 102.4 BTU/HR | |
|
|
|
| 62 Watts | 211.6 BTU/HR |
|
|
|
98 Watts | 334.5 BTU/HR | |
|
|
|
155 Watts | 520.0 BTU/HR | |
|
|
|
105 Watts | 358.3 BTU/HR | |
|
|
|
155 Watts | 520.0 BTU/HR | |
|
|
|
155 Watts | 520.0 BTU/HR | |
|
|
|
Table A-4 Redundancy Configurations for AC Line 100–120 Vac
No. of Power Supplies | Maximum Redundant System Load1 | Redundancy Configuration |
2 | 1160 Watts | 1 + 1 |
|
|
|
3 | 2320 Watts | N + 1 |
|
|
|
4 | 3480 Watts | 1 + 1 |
|
|
|
4 | 3480 Watts | N + 1 |
|
|
|
5 | 4640 Watts | N + 1 |
|
|
|
6 | 5800 Watts | 1 + 1 |
|
|
|
6 | 5800 Watts | N + 1 |
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Table A-5 Redundancy Configurations for AC Line 200–240 Vac
No. of Power Supplies | Maximum Redundant System Load1 | Redundancy Configuration |
2 | 1500 Watts | 1 + 1 |
|
|
|
3 | 3000 Watts | N + 1 |
|
|
|
4 | 3000 Watts | 1 + 1 |
|
|
|
4 | 4500 Watts | N + 1 |
|
|
|
5 | 6000 Watts | N + 1 |
|
|
|
6 | 4500 Watts | 1 + 1 |
|
|
|
6 | 6000 Watts | N + 1 |
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Matrix