Enterasys Networks X16-C manual Table A-3 Module Power Specifications

Models: X16-C

1 94
Download 94 pages 21.91 Kb
Page 83
Image 83

Power Supply Requirements, Specifications, and Twist Lock Options

Table A-3 Module Power Specifications

 

@ 110 Vac / 220 Vac

 

 

 

Module

Power (Watts)

Thermal Output (BTU/HR)

 

 

 

CM

97 Watts

331.1 BTU/HR

 

 

 

Fan tray

85 Watts

290.1 BTU/HR

 

 

 

X4-FM

30 Watts

102.4 BTU/HR

 

 

 

X8-FM

62 Watts

211.6 BTU/HR

 

 

 

X16-FM

98 Watts

334.5 BTU/HR

 

 

 

X-G32-00

155 Watts

520.0 BTU/HR

 

 

 

X-GT16-00

105 Watts

358.3 BTU/HR

 

 

 

X-M2-00

155 Watts

520.0 BTU/HR

 

 

 

X-T32-00

155 Watts

520.0 BTU/HR

 

 

 

Table A-4 Redundancy Configurations for AC Line 100–120 Vac

No. of Power Supplies

Maximum Redundant System Load1

Redundancy Configuration

2

1160 Watts

1 + 1

 

 

 

3

2320 Watts

N + 1

 

 

 

4

3480 Watts

1 + 1

 

 

 

4

3480 Watts

N + 1

 

 

 

5

4640 Watts

N + 1

 

 

 

6

5800 Watts

1 + 1

 

 

 

6

5800 Watts

N + 1

1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.

Table A-5 Redundancy Configurations for AC Line 200–240 Vac

No. of Power Supplies

Maximum Redundant System Load1

Redundancy Configuration

2

1500 Watts

1 + 1

 

 

 

3

3000 Watts

N + 1

 

 

 

4

3000 Watts

1 + 1

 

 

 

4

4500 Watts

N + 1

 

 

 

5

6000 Watts

N + 1

 

 

 

6

4500 Watts

1 + 1

 

 

 

6

6000 Watts

N + 1

1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.