Setup & Operation 3. Environments and Installation
G3 Rev.1 29
3.5 Installation Procedure
The following sections describe the installation of the Standard Manipulator.
3.5.1 Table Top Mounting
3.5.2 Multiple Mounting
For Cleanroom-model manipulator, refer to this section;
3.5.3 Cleanroom-model

3.5.1 Table Top Mounting

CAUTION
Install the Table Top Mounting Manipulator with two or more people.
The Manipulator weights are as follows. Be careful not to get hands, fingers, or
feet caught and/or have equipment damaged by a fall of the Manipulator.
G3-251S : approx. 27 kg: 60 lb.
G3-301S : approx. 27 kg: 60 lb.
G3-351S : approx. 28 kg: 62 lb.
Standard-model
20 mm
4-M8
×
40
Screw Hole
Spring
Washer
Plane
Washer
(depth 20 mm
or more)
(1) Secure the base to the base table with
four bolts.
Use bolts with specifications conforming
to ISO898-1 Property Class: 10.9 or
12.9.
(2) Using nippers, cut off the wire tie
binding the shaft and arm retaining
bracket on the base.
(3) Remove the bolts securing the wire ties
removed in step (2).
)
NOTE
Bolt
:M4×15
Bolt
:M8×20
Wire tie
Sheet