Setup & Operation 3. Environments and Installation

3.8.2Table Top Mounting

CAUTION

Install or relocate the Table Top Mounting Manipulator with two or more people. The Manipulator weights are as follows. Be careful not to get hands, fingers, or feet caught and/or have equipment damaged by a fall of the Manipulator.

G3-251S : approx. 27 kg: 60 lb.

G3-301S : approx. 27 kg: 60 lb.

G3-351S : approx. 28 kg: 62 lb.

NOTE

)

(1)Turn OFF the power on all devices and unplug the cables.

Remove the mechanical stops if using them to limit the motion range of Joints #1 and #2. For details on the motion range, refer to Setup & Operation: 5.2 Motion Range Setting by Mechanical Stops.

(2)Cover the arm with a sheet so that the arm will not be damaged.

Tie the lower end of the shaft and arm, and the base and arm together with a wire tie.

Be careful not to tie them too tight. Otherwise, the shaft may bend.

Example of Arm Retaining Posture

Wire tie

Bolt

:M820Bolt

:M415

Sheet

(3)Hold the bottom of Arm #1 by hand to unscrew the anchor bolts. Then, remove the Manipulator from the base table.

36

G3 Rev.1

Page 46
Image 46
Epson G3 Series manual Table Top Mounting