Setup & Operation 5. Motion Range

Table Top Mounting - Right-Curved Arm

Center of Joint#3

Maximum space

Motion range

Area limited

by mechanical stop

Base mounting face

 

 

a

b

c

d

e

f

g

h

j

k

m

 

 

 

G3-301S-R

125°

150°

135°

3.3°

150°

79.5

86.8

113.2

120.7

 

 

 

 

G3-301C-R

150°

125°

145°

8.3°

145°

 

 

 

 

 

 

 

 

 

 

 

 

G3-351S-R

110°

165°

120°

3.8°

165°

96.9

100.3

183.0

191.6

 

 

 

 

G3-351C-R

160°

107.5

184.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n

p

q

r

s

t

u

v

w

x

y

 

z

 

G3-301S-R

170

300

227.5

241.5

277.2

281.4

150

9.6

6.7

138.3°

153.3°

 

 

 

G3-301C-R

201.8

227.5

288.7

120

4.1

10.7

 

8.3°

 

 

 

 

 

 

 

 

 

 

G3-351S-R

220

350

205.2

219.4

342.5

346.6

150

9.6

6.7

123.8°

167.8°

 

2.8°

 

 

G3-351C-R

222.9

120

4.1

10.7

 

7.8°

 

 

 

 

 

 

 

 

 

 

 

(°: degree)

60

G3 Rev.1

Page 70
Image 70
Epson G3 Series manual G3-301S-R