CONFIDENTIAL
Paper roll Character commands ESC &
Ver. 10.0 1 p. 117
TM-U210
The dots adjoining each other horizontally cannot be printed. Only the MSB can be printed in the
second byte for vertical direction.
This command is effective only when the receive buffer capacity is 40 bytes (when DIP switch 1-2
is ON). The maximum number of user-defined characters is 19. When the maximum number of
user-defined characters is defined, it is possible to redefine user-defined characters for the
defined ASCII code, but not for the new ASCII code.
TM-U300A/B
The dots adjoining each other horizontally cannot be printed. Only the MSB can be printed in the
second byte for vertical direction.
The maximum number of user-defined characters differs, depending on the receive buffer
capacity as described below. When the maximum number of user-defined characters is defined, it
is possible to redefine user-defined characters for the defined ASCII code, but not for the new
ASCII code.
Japanese model Other than Japanese model
Models Maximum number of user-defined characters
Multiple characters 8
Other than multiple characters 19
Receive buffer
capacity
Maximum number of
user-defined characters
Receive buffer
capacity
Maximum number of
user-defined characters
512 bytes 4 1K bytes 9
40 bytes 20 40 bytes 44
0 bytes 22 0 bytes 44