CONFIDENTIAL
Paper roll Tw o-dimension code commands GS ( k
Ver. 10.0 1 p. 519
GS ( k <Function 068>
[Name] PDF417: Set the row height
[Format] ASCII GS ( k
pLpHcn fn n
Hex 1D 28 6B
03 00 30 44 n
Decimal 2940107
3 0 48 68 n
[Range] (
pL
+
pH
× 256) = 3 (
pL
= 3,
pH
=0)
cn
= 48
fn
= 68
TM-T90, TM-L90:2
n
8
[Default] TM-T90, TM-L90:
n
= 3
[Description] Sets the row height for PDF417 to [
n
× (the width of the module)].
[Notes] Settings of this function affect the processing of Functions 081 and 082.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is
turned off.
[Model-dependent variations] TM-T90, TM-L90
TM-T90
The module height influences the recognition rate of the symbol.
The module height is recommended to be set to 3-5 times the module width.
The recognition rate might decrease when the vertical size of the symbol is 5 mm {0.2"} or less.
The vertical size of the symbol can be confirmed by the transmission data of Function 082.
TM-L90
The module height influences the recognition rate of the symbol.
The module height is recommended to be set to 3-5 times the module width.
The recognition rate might decrease when the vertical size of the symbol is 5 mm {0.2"} or less.
The vertical size of the symbol can be confirmed by the transmission data of Function 082.