CONFIDENTIAL
Paper roll Miscellaneous commands DLE DC4 (fn = 7 )
Ver. 10.01 p. 391
TM-P60
The setting of Memory switch [Msw8-1] doesn’t affect the result of this command.
The battery status is a status that is automatically transmitted. The status is transmitted in the
following cases.
■The printer is booted by turning the power on, or resetting printer. (When Memory switch
[Msw8-1] is ON)
■The “Power source” in the status is changed.
■The “Battery remaining amount“ in the status is changed.
■The printer processes this command.
The transmitted battery status from this printer is constructed by [Header ~ NUL] as shown in the
following table.
(*1) “Power source“ is as indicated in the following table.
Transmitted data Hex Decimal Amount of data
Header 37H 55 1 byte
Identifier 45H 69 1 byte
Power source (*1) 30H or 31H 48 or 49 1 byte
Battery remaining
amount (*2)
30H ~ 34H 48 ~ 52 1 byte
NUL 00H 0 1 byte
Power source Information
Hex Decimal
30H 48 power provided from AC adapter
31H 49 power provided from battery