CONFIDENTIAL
Paper roll Miscellaneous commands DLE DC4 (fn = 7 )
Ver. 10.01 p. 391
TM-P60
The setting of Memory switch [Msw8-1] doesn’t affect the result of this command.
The battery status is a status that is automatically transmitted. The status is transmitted in the
following cases.
The printer is booted by turning the power on, or resetting printer. (When Memory switch
[Msw8-1] is ON)
The “Power source” in the status is changed.
The “Battery remaining amount“ in the status is changed.
The printer processes this command.
The transmitted battery status from this printer is constructed by [Header ~ NUL] as shown in the
following table.
(*1) “Power source“ is as indicated in the following table.
Transmitted data Hex Decimal Amount of data
Header 37H 55 1 byte
Identifier 45H 69 1 byte
Power source (*1) 30H or 31H 48 or 49 1 byte
Battery remaining
amount (*2)
30H ~ 34H 48 ~ 52 1 byte
NUL 00H 0 1 byte
Power source Information
Hex Decimal
30H 48 power provided from AC adapter
31H 49 power provided from battery