CONFIDENTIAL
Paper roll Customize commands GS ( E
Ver. 10.0 1 p. 610
[Description] Sets the configuration item for the serial interface specified by
a
to the values specified by
d1...dk
.
Transmission speed (
a
= 1) is specified by number. The baud rate that can be specified differs,
depending on the printer model.
Example: When defining 19200 bps: 5 bytes as “19200” (Hexadecimal = 31H, 39H, 32H, 30H, 30H / Decimal
= 49, 57, 50, 48, 48)
Parity (
a
= 2) is specified by
d
as follows:
Flow control (
a
= 3) is specified by
d
as follows:
Data length (
a
= 4) is specified by
d
as follows:
[Notes] It is recommended that the DIP switch be used to change communication condition.
a
Configuration item
1 Transmission speed
2 Parity
3 Flow control
4 Data length
d
Function
48 Select no parity
49 Select odd parity
50 Select even parity
d
Function
48 Select Flow control of DTR/DSR
49 Select Flow control of XON/XOFF
d
Function
55 Select 7 bits length
56 Select 8 bits length