CONFIDENTIAL
Paper roll Print position commands GS W
Ver. 10.0 1 p. 189
GS W SETTING COMMAND
[Name] Set print area width
[Format] ASCII GS W
nL
nH
Hex 1D 57
nL
nH
Decimal 29 87
nL
nH
[Range] 0 ≤ (
nL
+
nH
× 256) ≤ 65535 (0 ≤
nL
≤ 255, 0 ≤
nH
≤ 255)
[Default] Entire printable area
TM-J2000/J2100:
nL
= 0,
nH
= 2 (when paper width is set to 82.5 mm)
nL
= 224,
nH
= 1 (when paper width is set to 76 mm)
nL
= 176,
nH
= 1 (when paper width is set to 69.5 mm)
nL
= 104,
nH
= 1 (when paper width is set to 57.5 mm)
TM-T90: [Other than Japanese model]
nL
= 0,
nH
= 2 (when paper width is set to 80 mm)
nL
= 128,
nH
= 1 (when paper width is set to 60 mm)
nL
= 104,
nH
= 1 (when paper width is set to 58 mm)
[Japanese model]
nL
= 64,
nH
= 2 (when paper width is set to 80 mm)
nL
= 180,
nH
= 1 (when paper width is set to 60 mm)
nL
= 164,
nH
= 1 (when paper width is set to 58 mm)
TM-T88III:
nL
= 0,
nH
= 2 (when paper width is set to 80 mm)
nL
= 104,
nH
= 1 (when paper width is set to 58 mm)
TM-L90: [when receipt is selected]
nL
= 64,
nH
= 2 (when paper width is set to 80 mm to 78 mm)
256 + (paper width - 38) × 8 (when paper width is set to 77 mm to 38 mm)
[when label paper is selected]
nL
= 48,
nH
= 2 (when paper width is set to 80 mm)
224 + (paper width - 38) × 8 (when paper width is set to 79 mm to 38 mm)
TM-L60II:
nL
= 112,
nH
= 1 (when thermal label paper is selected)
nL
= 128,
nH
= 1 (when thermal label is selected)
TM-P60:
nL
= 164,
nH
= 1 (when paper width is set to 58 mm)
nL
= 176,
nH
= 1 (when paper width is set to 60 mm)
Print position commands