CONFIDENTIAL
Paper roll Miscellaneous commands ESC ( A
Ver. 10.0 1 p. 405
c
specifies the beeps integrated beeper/ not beeps integrated beeper when specified offline is
occurred.
•1
t1
50
specify beeping time (
t1
× 100 ms).
t1
= 255 specify beeping time (infinity).
t2
specify time for stop beeping (
t2
× 100 ms).
[Notes] This function repeats integrated beeper control of [(
t1
× 100 ms) beep/ (
t2
100 ms) stop] when offline
factors have occurred. However, (
t1
= 255) causes continuous beeping.
When the printer is offline, the integrated beeper will stops under any of the following conditions:
The offline factor is cleared.
The FEED switch is pressed.
Reset or power off.
Setting of this function is enabled until reset or power off.
c
Beeping method
0 Beeps integrated beeper
255 Does not beep the integrated beeper