CONFIDENTIAL
Paper roll Tw o-dimension code commands GS ( k
Ver. 10.0 1 p. 530
GS ( k <Function 165>[Name] QR Code: Select the model
[Format] ASCII GS ( k
pLpHcn fn n1 n2
Hex 1D 28 6B
04 00 31 41 n1 n2
Decimal 2940107
4 0 49 65 n1 n2
[Range] (
pL
+
pH
× 256) = 4 (
pL
= 4,
pH
= 0)
cn
= 49
fn
= 65
n1
= 49, 50
n2
= 0
[Default]
n1
= 50,
n2
= 0
[Description] Selects the model for QR Code.
[Notes] ■Settings of this function affect the processing of Functions 181 and 182.
■Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned
off.
[Model-dependent variations] TM-T90
TM-T90
This model does not support this function.
n1
Function
49 Selects model 1.
50 Selects model 2.