CONFIDENTIAL
Paper roll Tw o-dimension code commands GS ( k
Ver. 10.0 1 p. 518
GS ( k <Function 067>[Name] PDF417: Set the width of the module
[Format] ASCII GS ( k
pLpHcn fn n
Hex 1D 28 6B
03 00 30 43 n
Decimal 2940107
3 0 48 67 n
[Range] (
pL
+
pH
×
256) = 3 (
pL
=3,
pH
=0)
cn
= 48
fn
= 67
TM-T90, TM-L90:2 ≤
n
≤
8
[Default] TM-T90
,
TM-L90:
n
= 3
[Description] Sets the width of the module for PDF417 to
n
dots.
[Notes] ■Settings of this function affect the processing of Functions 081 and 082.
■The setting unit differs, depending on the printer models.
■Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned
off.
[Model-dependent variations] TM-T90, TM-L90
TM-T90
The setting unit is 1 dot.
With all models other than the Japanese model, the width is set in units of 0.141 mm {1/180 inch}.
With the Japanese model, the width is set in units of 0.125 mm {1/203 inch}.
TM-L90
The setting unit is 1 dot. The width is set in units of 0.125 mm {1/203 inch}.