CONFIDENTIAL
Paper roll Tw o-dimension code commands GS ( k
Ver. 10.0 1 p. 531
GS ( k <Function 167>
[Name] QR Code: Set the size of module
[Format] ASCII GS ( k
pLpHcn fn n
Hex 1D 28 6B
03 00 31 43 n
Decimal 2940107
3 0 49 67 n
[Range] (
pL
+
pH
×
256) = 3 (
pL
= 3,
pH
= 0)
cn
= 49
fn
= 67
TM-L90:1
n
16
[Default] TM-L90:
n
= 3
[Description] Sets the size of the module for QR Code to
n
dots.
[Notes] Settings of this function affect the processing of Functions 181 and 182.
The setting unit differs, depending on the printer models.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned
off.
n
= width of a module = height of a module. (Because the QR code modules are square. )
[Model-dependent variations] TM-T90, TM-L90
TM-T90
This model does not support this function.
TM-L90