CONFIDENTIAL
Paper roll Print position commands ESC W
Ver. 10.0 1 p. 176
[Default] TM-L90: [when the receipt is selected]
dxL
= 64,
dxH
= 2 (when paper width is set to 80 mm to 78 mm)
(256 + (paper width – 38) × 8) (when paper width is set to 77 mm to 38 mm)
dyL
= 196,
dyH
= 5
[when the label paper is selected]
dxL
= 48,
dxH
= 2 (when paper width is set to 80 mm)
(224 + (paper width – 38) × 8) (when paper width is set to 79 mm to 38 mm)
dyL
= 196,
dyH
= 5
TM-L60II:
dxL
= 112,
dxH
= 1,
dyL
= 126,
dyH
= 6 (when thermal label paper is selected)
dxL
= 128,
dxH
= 1,
dyL
= 126,
dyH
= 6 (when thermal paper is selected)
TM-P60:
dxL
= 164,
dxH
= 1,
dyL
= 176,
dyH
= 4 (when paper width is set to 58 mm)
dxL
= 176,
dxH
= 1,
dyL
= 176,
dyH
= 4 (when paper width is set to 60 mm)
[Printers not featuring this command] TM-U230, TM-U220, TM-U210, TM-U300A/B
[Description] In page mode, sets the size and the logical origin of the print area as follows:
Horizontal logical origin = (
xL
+
xH
× 256) × (horizontal motion unit) from absolute origin.
Vertical logical origin = (
yL
+
yH
× 256) × (vertical motion unit) from absolute origin.
Print area width = (
dxL
+
dxH
× 256) × (horizontal motion unit)
Print area height = (
dyL
+
dyH
× 256) × (vertical motion unit)
[Notes] Both print area width and height cannot be set to 0.
The absolute origin is the upper left of the printable area.
If the horizontal or vertical logical origin is set outside the printable area, this command is canceled, and
the following data is processed as normal data.
If [horizontal logical origin + print area width] exceeds the printable area, the print area width is
automatically set to [horizontal printable area – horizontal logical origin].
If [vertical logical origin + print area height] exceeds the printable area, the print area height is
automatically set to [vertical printable area – vertical logical origin].
The print area and the logical origin set by this command are effective only in page mode.
This command setting has no effect in standard mode. If this command is processed in standard mode, the
logical origin and the print area are set, and they are enabled when the printer selects page mode.