Annex B
B.7 | Power Supply – AC Mains Input | |
| This equipment is fitted with a | |
| voltages of | |
| Table B.25 AC Power Supply Specification | |
|
|
|
| Item | Specification |
| Power distribution system | Type TN ONLY (EN |
|
| system which is directly earthed, the parts of the equipment |
|
| required to be earthed being connected by protective |
|
| earthing conductors. This equipment must NOT be used |
|
| with |
|
| distribution systems. |
|
|
|
| Connection to supply | Pluggable Equipment Type A (EN |
|
| Equipment which is intended for connection to the building |
|
| power supply wiring via a |
|
| |
|
| Correct mains polarity must always be observed. Do not |
|
| use reversible plugs with this equipment. |
|
|
|
| Class of equipment | Class I Equipment (EN |
|
| protection by basic insulation and protective earth. |
|
|
|
| Rated voltage | |
|
|
|
| Rated frequency | 50/60 Hz |
|
|
|
| Voltage selection | |
|
|
|
| Rated current | RX83xx: 1 A |
|
| RX82xx: 1.5 A |
|
|
|
| Input connector | CEE 22/IEC |
|
|
|
| Fuse | Fuse in live conductor in power input filter at rear of unit. Do |
|
| not use reversible plugs with this equipment. |
|
|
|
| Fuse type | Bussmann S505 |
|
| Littelfuse 215 |
|
| 5x20 mm time delay (T) 1500 A breaking capacity (HBC) |
|
| IEC/EN |
|
|
|
| Fuse current rating | All RX8000 models: 2 A 250 V T HBC |
|
|
|
| Power consumption | 45 W typical (NO options fitted) |
|
| 60 W maximum |
|
|
|
B.8 Cable Types
The signal cable types (or similar) in Table B.26 are those recommended by
Ericsson in order to maintain product EMC compliance.
EN/LZT 790 0005 R1A |