Chapter 3
To edit the Gateway address:1.Press the Edit key. The cursor appears below the first character of the Gateway address.
2.Edit the address as required using the W (Back) and X (Forward) keys to select each digit in turn, and then using the S (Up) and T (Down) keys to increment or decrement the digit.
3.Press Save to save the new settings or Edit to abandon the operation and return to the current setting.
3.5.1.1.61.1.6 StatusThis menu displays the status of the IP control interfaces. To access the Status menu, press the T (Down) key. The following screen is displayed:
STATUS | CTRL 1 LINK STATUS Down |
When Status menu details have been viewed, press the W (Back) key to return to the Network
The Build menu allows the viewing of all equipment SW, FW and HW Version numbers. To access the Build menu, press the T (Down) key. The following screen is displayed:
BUILD Version1.2SW, FW, HW3.5.1.2.11.2.1 SW VersionTo view the software (SW) version, press the X (Forward) key. The following screen is displayed:
VERSIONS SW VERSION1.2.14.3.2 (Bank 0)3.5.1.2.21.2.2 PS VersionTo view the PS version, press the T (Down) key. The following screen is displayed:
VERSIONS PS VERSION1.2.20.14EN/LZT 790 0005 R1A |