Chapter 3
SETUP | ATM | HEADER ERR IGNORE | FALSE |
2.2.2.7 | ATM | VPI | 017 |
|
|
|
|
1.Press the Edit key. The cursor appears below the displayed type (FALSE shown above).
2.Use the S (Up) and T (Down) keys to toggle between the available options: TRUE and FALSE (dependent on model and option licences obtained).
3.Press Save to save the new settings or Edit to abandon the operation and return to the current setting.
4.Use the X (Forward) and W (Back) keys to toggle between the ATM Header Err Ignore and ATM VPI inputs.
To select the ATM VPI value:1.Press the Edit key. Press the X (Forward) key until cursor appears below the current value.
2.Use the S (Up) and T (Down) keys until the required value is obtained.
3.Press Save to save the new settings or Edit to abandon the operation and return to the current setting.
3.5.5.2.2.82.2.2.8 Sync CNT To Lock/Sync Miss Sample SizeTo access the Sync CNT To Lock/Sync Miss Sample Size Setup function, press the T (Down) key. The following screen is displayed:
SETUP | SYNC | CNT TO LOCK | 008 |
2.2.2.8 | SYNC | MISS SAMPLE SIZE | 030 |
|
|
|
|
1.Press the Edit key.
2.Use the S (Up) and T (Down) keys until the required value is obtained.
3.Press Save to save the new settings or Edit to abandon the operation and return to the current setting..
To select the Sync Miss Sample Size value:1.Press the Edit key. Press the X (Forward) key until cursor appears below the current value.
2.Use the S (Up) and T (Down) keys until the required value is obtained.
3.Press Save to save the new settings or Edit to abandon the operation and return to the current setting.
EN/LZT 790 0005 R1A |