Annex B

Table B.26 Suitable Signal Cable Types

 

 

 

 

Signal Type

Connector

Cable

 

 

 

Alarm Relay

9-way D-type Male

Belden 8162 CM 2PR24 shielded E108998

 

 

(typical)

 

 

 

ASI Out 1 and 2

BNC

Canford Audio BBC 1/3 PSF (type 2 video

 

 

cable)

 

 

 

ASI/SD-SDI/HD-SDI

BNC

Canford Audio BBC 1/3 PSF (type 2 video

Out 1, 2 and 3

 

cable)

 

 

 

ASI In

BNC

Canford Audio BBC 1/3 PSF (type 2 video

 

 

cable)

 

 

 

Ethernet/IP (Gbit)

RJ-45

CAT 5E Data Cable S-FTP

 

 

 

Audio 1 and 2 or 3

9-way D-type Male

Canford Audio Cable DST 110 Ω

and 4

to XLR

 

 

 

 

Audio 1 and 2 or 3

9-way D-type Male

Canford Audio Cable DST 110 Ω

and 4

to screw terminal

 

 

 

 

Frame Sync

BNC

Canford Audio BBC 1/3 PSF (type 2 video

 

 

cable)

 

 

 

RF IN

F - type

Belden 1694A 3 GHz cable

 

 

 

Video Out

BNC

Canford Audio BBC 1/3 PSF (type 2 video

 

 

cable)

 

 

 

Component Video Out

15-way D-type

Five-way screened Haurtian computer

 

Male

cable EL164535 ‘D’

 

 

 

Control 1 and 2

RJ-45

CAT 5E Data Cable S-FTP

(100BaseT)

 

 

 

 

 

Technical Earth

6.3 mm earthed tab

Green/Yellow earth cable or similar

 

 

 

B.9 Compliance7

B.9.1 Safety

This equipment has been designed and tested to meet the requirements of the following:

EN 60950-1

European

Information technology equipment - Safety.

 

 

 

IEC 60950-1

International

Information technology equipment - Safety.

 

 

 

UL 60950-1

USA

Information Technology Equipment - Safety.

 

 

 

7The version of the standards shown is that applicable at the time of manufacture.

EN/LZT 790 0005 R1A