SUPREMA 2001 - OPERATION & SERVICE MANUAL
SETTING THE DEFAULT1.To program the default settings, press the "UP" button on the hidden menu scroll buttons and scroll until the following message appears,
SET DEFAULT
PRESS <START>
a)Press the "START" button to enter the set mode.
b)The LED's that correspond to the current default setting will now be illuminated.
c)To change the default, press the buttons on the selection panel for the new default settings. The LED's that are illuminated will now become the new default settings.
d)In no default is set, the LED’s on the selection panel will light and scroll until the user selects one. This applies for the products, strengths, and cup sizes, therefore three selections will be required by the user.
e)To exit the "SET DEFAULT" mode and proceed to the next setting, press the "UP" or "DOWN" scroll buttons.
SETTING TOP PAUSE!Note:
The minimum setting for the “TOP PAUSE” is 2.0 seconds.
The “TOP PAUSE” occurs when the brewer is at top dead center, and is before the regular pause. When the piston reaches top dead center in the cylinder, the brewer will pause for the amount of time set in this menu, to allow the coffee and water to steep (mix together). The higher the "TOP PAUSE" is set to, the stronger the cup of coffee that is brewed by the equipment.
1.To set the "TOP PAUSE" setting, press the "UP" button on the hidden menu scroll buttons and scroll until the following message appears,
SET TOP PAUSE
PRESS <START>
a)Press the "START" button to enter the set mode.
b)At this point, select the cup size by pressing the appropriate buttons on the selection panel. The "TOP PAUSE" setting displayed will correspond to the cup size that is illuminated.
c)Using the hidden setting adjustment buttons, increase or decrease the timing for the "TOP PAUSE".
d)To exit the "SET TOP PAUSE" mode and proceed to the next setting, press the "UP" or "DOWN" scroll buttons.
Page 20 of 60 | July 6, 2001 | Suprema 2001 - Operation & Service |