SUPREMA 2001 - OPERATION & SERVICE MANUAL

REMOVING THE WATER TANK ASSEMBLY

1.Switch the coffee maker "OFF".

2.Drain the water tank.

a)Place a heat-resistant and leak-proof container beneath the water tank.

b)Remove the top clip on the drain plug and push the drain plug upwards. The bottom clip will act as a stopper.

CAUTION: Water coming out of the water tank may be extremely hot. Use caution when removing the outlet valves.

3.Remove the brewer.

4.Disconnect the inlet hose.

a)Remove the hose clamp securing the inlet hose to the inlet fitting.

5.Remove the valve cover on the water tank.

6.Remove the hose from the hot water valve.

7.Remove the hose fitting from the whipper motor (if installed).

8.Disconnect the water tank harness from the rear board.

9.Disconnect the temperature probe harness from the rear board.

10.Disconnect the wires identified in the table below.

WIRE

CONNECTED TO:

#1-2on General Harness

Whipper Motor

#8-1on General Harness

Whipper Motor

#11-1on Tank Harness

Wire #3-2on Fuse Box Harness

#6 on Tank Harness

Inlet Valve

#1-2on Tank Harness

Inlet Valve

#11 on Fuse Box Harness

Stud #3 on Heater Relay

#13-1(ground wire)

Ground Stud on Rear Board Cover

*For more information about wiring, consult the wiring section of this manual.

11. Carefully slide the water tank forward and out of the machine.

Page 46 of 60

July 6, 2001

Suprema 2001 - Operation & Service