SUPREMA 2001 - OPERATION & SERVICE MANUAL
SETTING THE FREQUENCY OF MESSAGES1.To program the frequency of messages, press the "UP" button on the hidden menu scroll buttons and scroll until the following message appears,
FREQ. OF MESSAGE
PRESS <START>
a)Press the "START" button to enter the set mode.
b)Using the hidden setting adjustment buttons, increase or decrease the timing for the frequency at which the messages are to appear.
c)To exit the "FREQUENCY" mode and proceed to the next setting, press the "UP" or "DOWN" scroll buttons.
SERVICE COUNTERThis is a counter that, when reset, starts at 6000 and decrements by one every time a product is dispensed. Once it reaches zero, the following message appears,
PLEASE CALL FOR
ROUTINE SERVICE
This message acts as a reminder that regular maintenance is due on the equipment. Please note that this feature can be canceled. For more information, please check the "CANCELING MESSAGES" section of this manual.
1.To reset the service counter, press the "UP" button on the hidden menu scroll buttons and scroll until the following message appears,
SERVICE COUNTER
PRESS <START>
a)Press the "START" button to enter the set mode.
b)Press the "START" button once more to reset the counter. The counter will now display 6000.
c)To exit the "SERVICE COUNTER" mode and proceed to the next setting, press the "UP" or "DOWN" scroll buttons.
Page 22 of 60 | July 6, 2001 | Suprema 2001 - Operation & Service |