SUPREMA 2001 - OPERATION & SERVICE MANUAL

MESSAGE

POSSIBLE CAUSE

CORRECTIVE ACTION

ENTER SET-UP

SET TEMPERATURE

The rear board is set for a mechanical thermostat, but the machine is equipped with an electronic temperature probe.

(Go to the “SET TEMPERATURE” menu and set the electronic temperature probe.

INCOMPATIBLE

SOFTWARE LEVEL

The software version (EPROM) in the Data Link downloader in not compatible with this equipment and will be downloaded.

(Replace the software version (EPROM) with one that is compatible with the Suprema model. The words “SUPREMA” will be printed on the EPROM decal.

PLEASE CALL FOR

This message is a reminder that regular

maintenance may be due and will not

ROUTINE SERVICE

stop the operation of the coffee maker.

 

(The coffee maker is due for routine maintenance.

(To reset the message, enter the "SET-UP"and reset the service counter.

PLEASE CHECK

The brewer harness is not connected to

the rear board.

BREWER HARNESS

 

(Connect the brewer harness to the rear board.

PLEASE CHECK

Overflow harness is not connected to

the rear board.

OVERFLOW HARNESS

 

(Connect the overflow harness to the rear board.

PLEASE CHECK

The water tank harness is not

connected to the rear board.

TANK HARNESS

 

(Connect the water tank harness to the rear board.

PLEASE CHECK

Indicates a problem with the main water

supply not getting to the water tank.

WATER SOURCE

 

(At this point, the water tank is not full and this message has to be reset. To reset it, switch the power off and on.

(If the problem persists, check all components on the water line (water filter, tubing, fittings, etc.).

(Check inlet valve to make certain it is functioning properly.

(In the case of a temporary disruption with the water supply, the coffee maker will reset itself after every hour.

PRESS PRODUCT

The "OPEN BREWER" button has been

( Pressed the "OPEN BREWER" button once

TO RESET MESSAGE

pressed.

more to close the brewer and exit.

 

( At this point, pressing the appropriate

 

 

 

 

buttons on the front selection panel will

 

 

reset the product counters.

PROBES

The main level probes are covered with

lime/calcium.

CALL FOR SERVICE

 

(The water tank may require deliming.

(The main level probes need to be cleaned/delimed.

SELECTION

Product selected may be disabled.

( Check the "ENABLE SWITCHES" menu to

 

see if product has been canceled.

NOT AVAILABLE

 

 

( Check the price of the selection to make

 

 

 

 

certain it has not been disabled (set

 

 

below zero).

Page 40 of 60

July 6, 2001

Suprema 2001 - Operation & Service