SUPREMA 2001 - OPERATION & SERVICE MANUAL
SETTING BOTTOM PAUSE DELAYThis feature allows a delay in the position of the bottom pause to obtain maximum vacuum and capacity in the brewer. For example, if this setting is at 0.5 seconds, the bottom pause will occur 0.5 seconds after the switch reads the pause position on the cam. The piston will stop lower in the cylinder, creating more vacuum and increasing the quantity of liquid that can be pulled into the cylinder.
1.To set the "DELAY PAUSE", press the "UP" button on the hidden menu scroll buttons and scroll until the following message appears,
DELAY PAUSE
PRESS <START>
a)Press the "START" button to enter the set mode.
b)Using the hidden setting adjustment buttons, increase or decrease the timing for the bottom pause delay.
c)To exit the "SET DELAY PAUSE" mode and proceed to the next setting, press the "UP" or "DOWN" scroll buttons.
CANCELING MESSAGES (MESSAGES ON, OFF or "ACTIVE")!Note:
The upper half of the display indicates which message is to be canceled, and the lower half of the display indicates the status of the message (ON-
PASSIVE,
or OFF). All new units are factory set with every message set to
!Note:
Each of the messages in the table can be individually set to
Please be aware that if a message is set to “ON- ACTIVE”, the function corresponding to that message will be disabled when the message appears. Make sure to inform the caretaker of the proper procedure required to clear the messages.
The following is a list of all the cancelable messages in this version of software. Most of these messages can also be programmed to be "active", meaning they will disable the unit until the message has been cleared. Use this chart as a quick reference.
CANCELABLE MESSAGES
Refill Large Hopper
Refill Small Hopper
Refill Chocolate
Empty Grounds
Call Key Operator
Service Message
Custom Messages
Temp. Too Low
1.To cancel one of the passive messages, or to make the message "active", press the "UP" button on the hidden menu scroll buttons until the following message appears,
MESSAGES ON/OFF
PRESS <START>
a)Press the "START" button to enter the set mode.
b)Scroll through the messages by pressing the "START" button.
c)To cancel a message or to make it "ACTIVE", once it is displayed on the LCD press either one of the two hidden setting adjustment buttons to switch it to "OFF" or " ON
d)Press “START” to save the settings.
e)To enable a message again, repeat the above procedure and switch the message to "ON" (either passive or active).
f)To exit, press one of the hidden scroll buttons.
Suprema 2001 - Operation & Service | July 6, 2001 | Page 23 of 60 |