SUPREMA 2001 - OPERATION & SERVICE MANUAL

TRANSFERRING SETTINGS FROM ONE SUPREMA TO ANOTHER

!Note:

Although the identical settings will be transferred from a preprogrammed unit to a non- programmed unit, some fine-tuning may be required for product and water settings. This is due to slight differences with the tolerances of certain components, such as valves, motors and ingredient dispensers.

Using the VKI Data Link downloader, it is possible to for you to transfer all the settings from one Suprema coffee maker, to one or several other Suprema coffee makers. For example, if a customer requests three Suprema coffee makers with the exact same settings, only one needs to be set up. Once the first unit is programmed, the settings can be loaded into the Data Link, and then downloaded from the Data Link to the other two units. This will eliminate the need to repeatedly program multiple units with the same settings. All the settings in the "SET-UP" mode will be transferred, with the exception of the counters.

To transfer settings from one Suprema coffee maker to another, the procedure outlined below must be performed. This needs to be done with the power to the coffee machine "ON".

STEP 1 - TRANSFERRING SETTINGS TO THE DATA LINK DEVICE

1.Connect the Data Link phone jack harness to the free connector on the back of the front board.

2.Press the "SET-UP" button on the back of the front board.

a)The following message will appear on the display,

COPY DATA LINK

TO SET-UP

3.Press the bottom scroll button to the right of the "START" button.

a)The following message will appear on the display,

COPY SET-UP TO

DATA LINK

4.Press the "START" button on the Suprema front selection panel.

a)The settings in the Suprema "SET-UP"will now be transferred to the Data Link device.

Suprema 2001 - Operation & Service

July 6, 2001