7.Near the bottom of this file are two values namedst_controlIp and st_localIp0 with an IP address listed under each (see figure 16). Edit these values as follows.

zz If the VNM Recorder is the controller device, edit both values to match the IP address (eth0) of the recorder.

zz If the VNM Recorder is not the controller device, change the st_controlIp value to match the IP address of the controller device. Change the st_localIp0 value to match the IP address (eth0) of the recorder.

Edit this value to match

the IP address of the controller device.

Edit this value to match the IP address (eth0) of the VNM Recorder.

Figure 16. Config.xml Text Window

NOTE:

Be careful not to change any other values or remove any of the special

formatting characters in this file.

8.Click on the save icon or click on the File menu and select the

Save (current buffer) option.

9.Close the text editor window and all other folder windows.