Mounting
This section outlines the various mounting options available for the VNM Recorder.
zz Tower Installation
zz Rack Installation
Tower Installation
Attach the appropriate feet to the unit and place it in a well ventilated area. The tower can be placed on its side (horizontally) on a hard surface with the cover latch facing up or placed standing up (vertically) on a flat surface.
Rack Installation
This section provides information on installing the recorder into a rack cabinet. Rack installation requires the use of the rack mount kit, which is included with the VNM Recorder.
There are a variety of rack cabinets on the market, which may mean the assembly procedure will differ slightly. If necessary, refer to the instructions that came with the rack cabinet to complete the rack installation.
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of these products in a rack:
1.Elevated operating ambient temperature — If the unit is installed in a closed or
2.Reduced air flow — Install the equipment in the rack so that the equipment gets adequate air flow for safe operation.
3.Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition.
4.Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Consider the equipment nameplate ratings when addressing this concern.
5.Reliable earthing (grounding) — Maintain reliable grounding of
VNM Recorder • Mounting | 72 |