Alarm Reference Tables

Alarm Type Description — Encoder

Alarm Type

Description

Action

Default Settings

 

 

 

 

 

 

 

 

No source

No source present at the input.

Check input connections; is

Critical, reporting

 

 

there an output on the loop

 

 

 

through connector?

 

 

 

 

 

Bad source syncs

Source is present, but

 

Critical, reporting

 

unrecognized due to bad sync

 

 

 

measurement.

 

 

 

 

 

 

No SDI source

Source is present, unable to lock.

 

Critical, reporting

lock

 

 

 

 

Applicable to the

 

 

 

VN-Matrix 300 / 325,

 

 

 

ignore for VN-Matrix 200 / 225.

 

 

 

 

 

 

Unsupported SDI

Source is present, mode not

 

Critical, reporting

mode

supported.

 

 

 

Applicable to the

 

 

 

VN-Matrix 300 / 325,

 

 

 

ignore for VN-Matrix 200 / 225.

 

 

 

 

 

 

Unsupported

Source is present, mode not

 

Critical, reporting

mode

supported.

 

 

 

 

 

 

Bad source

 

 

Critical, reporting

 

 

 

 

Analog phasing

 

 

Warning, reporting

error

 

 

 

 

 

 

 

Hardware

The hardware is unable to encode

 

Critical, reporting

encoding error

the input signal.

 

 

 

 

 

 

Unsupported

 

 

Critical, reporting

audio source

 

 

 

 

 

 

 

Data rate overload

The compressed data rate is too

Increase the compression or

Critical, reporting

 

high.

reduce the required bit rate.

 

 

 

 

 

Network overload

The network is dropping too

 

Warning, reporting

 

many packets.

 

 

 

 

 

 

VNM Recorder • About Alarms

60

Page 66
Image 66
Extron electronic 68-1998-01 REV. C manual Alarm Reference Tables, Alarm Type Description Encoder