Alarm Type Description — Decoder

Alarm Type

Description

Action

Default Settings

 

 

 

 

 

 

 

 

No decoder video

Indicates that there is a valid

 

Warning, reporting

data

connection, no video data

 

 

 

present. Usually accompanied by

 

 

 

"no source data stream" message

 

 

 

in the web interface.

 

 

 

 

 

 

No decoder mode

No matching decoder mode for

 

Warning, reporting

 

the incoming stream.

 

 

 

 

 

 

No source report

Unable to detect the format of

 

Warning, reporting

 

the received data stream.

 

 

Recovered audio

 

 

Warning, reporting

 

 

 

 

No decoder audio

 

 

Warning, reporting

data

 

 

 

 

 

 

 

Bad audio at decoder

 

 

Warning, reporting

Bad audio PLL

 

 

Warning, reporting

 

 

 

 

Video network

Excessive network packet loss has

 

Warning, reporting

packets dropped

occurred.

 

 

 

 

 

 

Decoder buffer

The incoming data rate is high;

 

Warning, reporting

overflow

reduce the pipeline delay.

 

 

Decoder buffer

The incoming data rate is too low;

 

Warning, reporting

underflow

increase the pipeline delay.

 

 

 

 

 

 

Bad video PLL

The decoder cannot synchronize

 

Warning, reporting

 

to the video data.

 

 

 

 

 

 

No decoder ANC data

The decoder is not receiving any

 

Warning, reporting

 

embedded audio (ancillary) data.

 

 

Missing ANC at

The Decoder is receiving poor

 

Warning, reporting

decoder

quality ANC data.

 

 

 

 

 

 

Recovered ANC

Error correction has recovered

 

Warning, reporting

 

corrupted / missing ANC.

 

 

 

 

 

 

No genlock source

Indicates that genlock is enabled,

Connect a valid genlock

Warning, reporting

present

but that there is no genlock

signal.

 

 

source connected.

 

 

No genlock source

Indicates that a signal is present

Check the format of the

Warning, reporting

lock

on the genlock connector, but it is

genlock signal.

 

 

not within the expected range.

 

 

 

 

 

 

Genlock source

Indicates that the timing of the

Connect a valid genlock

Warning, reporting

mismatch

genlock signal does not match the

signal.

 

 

format of the decoded source.

 

 

Alarm Type Description — System Controller

Alarm Type

Description

Action

Default Settings

 

 

 

 

Bad device

The controller is unable to contact

Check the device in question.

Critical, reporting

 

the specified device. The device is

Is power applied?

 

 

not available or has failed.

Is the network cable or

 

 

Note that this alarm is only

network connection present?

 

 

generated on the controller.

Has the unit been removed?

 

 

 

 

 

VNM Recorder • About Alarms

61

Page 67
Image 67
Extron electronic 68-1998-01 REV. C manual Alarm Type Description Decoder, Alarm Type Description System Controller