Extron electronic USP 507 manual SIS Programmer’s Guide, cont’d, E X^Phas

Models: USP 507

1 96
Download 96 pages 45.48 Kb
Page 44
Image 44
E X^PHAS}

SIS Programmer’s Guide, cont’d

Command

 

ASCII command

Response

Additional description

 

 

(host to processor\⤀

(processor to host\⤀

 

 

 

 

 

 

Pixel phase

 

 

 

 

Specify a value

E X^PHAS}

PhasX!*X^]

Set pixel phase to specified

 

 

 

 

value for active input.

Increment value

E+PHAS}

PhasX!*X^]

Increase value.

Decrement value

E-PHAS}

PhasX!*X^]

Decrease value.

View value

 

EPHAS}

X^]

Show pixel phase.

 

 

 

Total pixels (RGB and YUVp/HDTV only\⤀

 

 

Specify a value

E X&TPIX}

TpixX!*X&]

Set total pixels to specified

 

 

 

 

value for active input.

Increment value

E+TPIX}

TpixX!*X&]

Increase value.

Decrement value

E-TPIX}

TpixX!*X&]

Decrease value.

View value

 

ETPIX}

X&]

Show total pixels.

Active pixels

 

 

 

Specify a value

E X*APIX}

ApixX!*X*]

Set active pixels to specified

 

 

 

 

value for active input.

Increment value

E+APIX}

ApixX!*X*]

Increase value.

Decrement value

E-APIX}

ApixX!*X*]

Decrease value.

View value

 

EAPIX}

X*]

Show active pixels.

Active lines

 

 

 

 

Specify a value

E X(ALIN}

AlinX!*X(]

Set active lines to specified

 

 

 

 

value for active input.

Increment value

E+ALIN}

AlinX!*X(]

Increase value.

Decrement value

E-ALIN}

AlinX!*X(]

Decrease value.

View value

 

EALIN}

X(]

Show active lines.

 

 

 

 

3:2/2:2 Film mode detect

 

 

 

Enable film mode

E X!*1FILM}

FilmX!*X1)]

Turn film mode detection on.

Disable film mode

E X!*0FILM}

FilmX!*X1)]

Turn film mode detection off.

View setting

 

E X!FILM}

X1)]

View setting.

Picture Adjustments

 

 

 

Video mute

 

 

 

 

Mute video to black

1B

Vmt1]

Mute video and display a black

 

 

 

 

screen.

Unmute video

 

0B

Vmt0]

Restore picture.

View mode

 

B

X1)]

Mute status is X1).

 

 

 

 

 

Freeze

 

 

 

 

Enable

 

1F

Frz1]

Freeze selected input.

Disable

 

0F

Frz0]

Unfreeze selected input.

View

 

F

X1)]

Freeze status is X1).

N X!

= Input selection

1-7

 

 

X^

= Pixel phase

0-31 (default = 16)

 

 

X& = Total pixels

(±512 of the default value)

 

X* = Active pixels

(±512 of the default value)

 

X( = Active lines

(±512 of the default value)

 

X1) = Off/disable/none (0), on/enable/black (1)

4-8 USP 507 • SIS Programmer’s Guide

Page 44
Image 44