Extron electronic manual Tools menu, USP 507 • USP 507 Software

Models: USP 507

1 96
Download 96 pages 45.48 Kb
Page 61
Image 61
Tools menu

Tools menu

Click on this to open a drop-down box displaying

nine selectable options: Data View/Trace Window...

Executive Mode, Sync Scaler to Matrix Switcher...,

System Settings..., Reset, and Update Firmware....

Data View/Trace Window... — Select this to open a separate window in which the transmit and receive (Tx/Rx) data between the control software on the host PC and the USP 507 can be viewed in ASCII format (see figure at right). During data transmission and receipt, the data tracer window is constantly updated. To close the window, click Close or the X in the window’s top right corner.

Executive Mode — Select this to open a secondary drop-down box, allowing selection between Input Switch/Freeze only, On, or Off. Select as desired.

Sync Scaler to Matrix Switcher — Select this to open a secondary window. Within that window enter the IP address

of the matrix switcher to which the USP 507 is connected. If required enter the (matrix) password, then click Connect to

Matrix. Select the output number from the Matrix Output to USP 507 drop-down list and click Take. The Matrix Status section displays the matrix output that is being monitored and the tied input. The USP 507 Input #3 section displays the current status of the input being used.

NThe matrix switcher must be connected via a configured input on the USP 507. See pages 3-14and 3-15 for information.

The matrix and the USP 507 must be connected to an active network at all

times to allow the products to remain synchronized. If the connection is lost, the script needs to be restarted by either sending the SIS command or by power cycling the USP 507.

Click Refresh Status to update the status of the matrix switcher. Refreshing the status returns updated information about which scaler input is tied to a particular matrix output.

If the matrix IP address needs to be changed or which output of the matrix the USP 507 is connected to, click Remove Sync Scripts.