Ethernet Connection

Ethernet Connection

Ethernet Link

The rear panel Ethernet connector on the USP 507 can be connected to an Ethernet LAN or WAN. This connection makes SIS control of the unit possible using a computer connected to the same LAN.

LAN

ACT LINK

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover cable and must be properly terminated for your application (figure B-1).

Crossover cable — Direct connection between the computer and the USP 507.

Patch (straight) cable — Connection of the USP 507 to an Ethernet LAN.

Pins:

1 2 3 4 5 6 7 8

Insert

Twisted

Pair Wires

RJ-45 Connector

Straight-through Cable

(for connection to a switch, hub, or router)

 

End 1

 

End 2

Pin

Wire Color

Pin

Wire Color

1

white-orange

1

white-orange

2

orange

2

orange

3

white-green

3

white-green

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

green

7

white-brown

7

white-brown

8

brown

8

brown

Crossover Cable

(for direct connection to a PC)

 

End 1

 

End 2

Pin

Wire Color

Pin

Wire Color

1

white-orange

1

white-green

2

orange

2

green

3

white-green

3

white-orange

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

orange

7

white-brown

7

white-brown

8

brown

8

brown

Figure B–1RJ-45 connector pinout tables

Default address

To access the USP 507 via the Ethernet port, you need the unit’s IP address. If the address has been changed to an address comprised of words and characters, the actual numeric IP address can be determined using the ping utility. If the address has not been changed, the factory-specified default is 192.168.254.254.

Ping can also be used to test the Ethernet link to the USP 507.

Ping to determine Extron IP address

The ping utility is available at the command (Cmd) prompt. Ping tests the Ethernet interface between the computer and the USP 507. Ping can also be used to determine the actual numeric IP address from an alias and to determine the Web address.

Ping the device as follows:

1.

From the Windows Start menu, select Run... . The Run window opens.

2.

In the Open text field, enter command.

B-2

USP 507 Ethernet Connection

Page 91
Image 91