Extron electronic USP 507 manual EX12%*X14#*X14$

Models: USP 507

1 96
Download 96 pages 45.48 Kb
Page 55
Image 55
EX12%*X14#*X14$*

Command

ASCII ⤀(Telnet\

URL Encoded ⤀(Web\

Response

Additional

 

(host to ⤀processor\

(host to ⤀processor\

(processor to ⤀host\

description

Configure redirect mode

EX12%*X14#*X14$*

WX12%%2AX14#%2AX14$

CpnX12%•CcdX14#,X14$,X13!]

X13!CD}

%2AX13!CD

 

 

Terminate redirect mode

EX12%*0CD}

WX12%%2A0CD

CpnX12%•Ccd00000,00000,

00000L]

 

 

 

Read redirect mode

EX12%CD}

WX12%CD

X14#,X14$,X13!]

 

 

 

 

Ethernet data port

 

 

 

Set current conn port timeout

E0*X14@TC}

W0%2AX14@TC

Pti0*X14@]

Read current conn port timeout

E0TC}

W0TC

X14@]

Set global IP port timeout

E1*X14@TC}

W1%2AX14@TC

Pti1*X14@]

Read global IP port timeout

E1TC}

W1TC

X14@]

 

 

 

 

Directories

 

 

 

Change/create directory

Epath/directory/CJ}

 

 

 

 

Back to root directory

E/CJ}

Up one directory

E~CJ}

View current directory

ECJ}

Wpath%2Fdirectory%2FCJ

Dir•path/directory/]

 

 

 

 

 

 

 

 

W%2FCJ

Dir•/]

 

 

 

 

 

 

 

W%2E%2ECJ

Dir•path/directory/]

 

 

 

 

 

WCJ

path/directory/]

 

 

 

 

 

 

 

 

USP 507 • SIS Programmer’s Guide 4-19

directory = A text string drawn from the alphabet (A-Z), digits (0-9), minus sign/hyphen (-). No blank or space characters are permitted as part of the name. No distinction is made between upper and lower case. The first character must be an alpha character.

NA directory does not truly exist until a file has been copied into that path.

Unlike various PC operating systems, a file and directory on the Extron product are allowed to have the same name. The current directory is a per-connection setting. It begins at the root for each IP session.

NX12% = Specific serial port number: 01-03, 01 = COM1, 02 = COM2, 03 = COM3

X13! = Parameter (#L or #D) to set either the Length of message to receive or the Delimiter value. # = byte count (for L) or # = a single ASCII character

expressed in decimal form (for D). The parameter is case sensitive. Byte count is 0 to 32767, (default = 0).

X14@ = IP connection timeout period specified in 10‑second steps , 1 - 65000, (default = 30 = 300 seconds). If no data is received in the specified period, the connection closes. X14# = Redirection status: 0 = no redirection, 1 - 3 = redirect serial communication

X14$ = Timeout period in tens of milliseconds for serial data pass-through mode, range = 1 - 32767, (default = 10 = 100 ms)